Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters

Database
Language
Document Type
Year range
1.
J Clin Med ; 12(7)2023 Mar 29.
Article in English | MEDLINE | ID: covidwho-2295217

ABSTRACT

Esophagogastroduodenoscopy (EGD) is an aerosol-generating procedure. A major challenge in the COVID-19 era is how to prevent the spread of aerosols and droplets in endoscopic units. We evaluated the effectiveness of an extraoral suction device in preventing indoor aerosol diffusion and droplet exposure for examiners. The study involved 61 patients who underwent EGD at our institution from 1 February to 31 March 2022. To determine whether aerosol spread increases before or after EGD examination with an extraoral suction device located in front of the patient's mouth, aerosols of 0.3, 0.5, 1, 3, 5, and 10 µm were measured with a handheld particle counter. The degree of contamination of the plastic gowns on the examiners was assessed using the rapid adenosine triphosphate test. The extraoral suction device significantly reduced the diffusion of large particles (3, 5, and 10 µm) after finishing the EGD examination. However, the diffusion of small particles (0.3 and 0.5 µm) was significantly increased. This extraoral suction device was effective in reducing large particle diffusion during EGD examination but was limited for minimizing small particle diffusion or droplet exposure to the examiner.

2.
Diagnostics (Basel) ; 11(9)2021 Sep 14.
Article in English | MEDLINE | ID: covidwho-1408829

ABSTRACT

Esophagogastroduodenoscopy (EGD) has a high risk of virus transmission during the current coronavirus disease 2019 era, and preventive measures are under investigation. We investigated the effectiveness of a newly developed patient-covering negative-pressure box system (Endo barrier®) (EB) for EGD. Eighty consecutive unsedated patients who underwent screening EGD with EB use were prospectively enrolled. To examine the aerosol ratio before, during, and after EGD, 0.3- and 0.5-µm aerosols were measured every 60 s using an optical counter. Moreover, the degree of contamination of the examiners' goggles and vinyl gowns was assessed before and after EGD using a rapid adenosine triphosphate (ATP) test for simulated droplets. Data were available in 73 patients and showed that 0.3- and 0.5-µm particles did not increase in 95.8% (70/73) and 94.5% (69/73) of patients during EGD under EB. There were no significant differences in the total 0.3- or 0.5-µm particle counts before versus after EGD. The difference in the ATP levels before and after EGD was -0.6 ± 16.6 relative light units (RLU) on goggles and 1.59 ± 19.9 RLU on gowns (both within the cutoff value). EB use during EGD may provide a certain preventive effect against aerosols and droplets, decreasing examiners' exposure to viruses.

4.
JGH Open ; 5(7): 825-826, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1269114

ABSTRACT

During the COVID-19 pandemic era, multiple infection prevention and control measures to reduce the risk of SARS-CoV-2 transmission may be required in upper gastrointestinal endoscopy (UGI). We herein studied the verification tests of Endo barrier, which is one of the protective barrier enclosures. Endo barrier may be an alternative for minimizing SARS-CoV-2 transmission during UGI.

SELECTION OF CITATIONS
SEARCH DETAIL